Description |
|
|
Type |
Residential
and Commercial RO
Systems - Standard Line |
|
Usage |
High
quality drinking water from Tap or Brackish
Water with maximum TDS of 1,500 mg/l |
|
Applications |
Water
for Drinking, Cooking, Water Coolers, Refrigerators, Icemakers,
Coffee Makers etc. for use at Home, Office or Restaurants |
|
Equipment |
These
Point of Use Systems are self contained, easy to install and
operate at low pressure and low recovery. Three-Stage
System: Sediment Pre-Filter, RO Purification (CTA), Carbon
Post-Filter Four-Stage
System: Sediment Pre-Filter, Carbon Pre-Filter, RO
Purification (TFC), Carbon Post-Filter Five-Stage
System: Sediment Pre-Filter, Dual Carbon Pre-Filters, RO
Purification (TFC), Carbon Post-Filter Each
system is offered with the following Standard Components:
Membrane Element: CTA 10 gpd for 3-stage systems,
TFC 18 gpd for 4&5-stage systems
Pressurized Tank: 3.2 gal Amtrol Tank
Faucet: Two position, Standard Long Reach, Chrome plated (STDLC)
Tubing: 1/4" for capacities less than 36 gpd;
3/8" for higher capacities
Auto Shut-off Valve: Self regulated automatic
shut-off for water conservation
Upgrades
and Add-ons are available for price adders. Please refer to Options
Section in the following table:
|
Description |
Model |
3-Stages
RO30 |
4-Stages
RO40 |
5-Stages
RO50 |
CTA
Std gpd |
Upgrades |
TFC
Std gpd |
Upgrades |
TFC
Std gpd |
Upgrades |
| Standard
Line |
RO30 |
10 |
A-1,
A-2
B-2
D-1 & D-2 |
--- |
--- |
--- |
--- |
| RO40 |
--- |
--- |
18 |
A-2
to A-6
B-1 to B-7
C-1
D-1 & D-2 |
18 |
A-2
to A-6
B-1 to B-7
C-1
D-1 & D-2 |
| RO50 |
--- |
--- |
18 |
A-2
to A-6
B-1 to B-7
C-1
D-1 & D-2 |
18 |
A-2
to A-6
B-1 to B-7
C-1
D-1 & D-2 |
|
|
Features |
|
| General |
1.
Operates on line pressure (50-80 psig) to achieve separation
2. Built-in Automatic Shut-off Valve for water
conservation
3. All materials are FDA and/ or NSF compliant
4. Limited 3-Years Factory Limited Warranty |
|
Pretreatment |
Micron
Filter: 5-micron Filament Wound Spun Cartridge for Sediment removal.
Carbon Pre Filter 1: 10-micron Extruded Carbon
Block for VOC, Chlorine, taste and odor removal
Carbon Pre Filter 2: GAC, Coconut shell for
Chlorine, taste and odor removal |
|
Main
Treatment |
RO
purification: Using CTA or TFC Membrane Elements to remove 90-95% of Dissolved Solids,
including sodium, calcium, magnesium, chlorides, nitrates, sulfates, phosphates, lead, copper, mercury, arsenic,
zinc, and
more. |
|
Post
Treatment |
Carbon
Post Filter: In-line GAC, Coconut shell for odor removal
and taste enhancement |
|
|
Advantages |
|
|
Design |
1.
Reliable, high quality components
2. All materials are FDA and/ or NSF compliant
3. Flexible, allows upgrades and add-ons
4. Compact, fits under sink or any other limited space
5. Economical, costs less $ 0.03 per gal of purified water
produced
6. Easy to install. Designed for Do It Yourselfers, just
by following instructions |
Operation |
1.
No
moving parts. Utilizing line pressure to achieve separation.
2. Booster Pump could be used where line pressure is low to increase
the feed water pressure to recommended pressure.
3. Reliable; Three Years Factory Limited Warranty
4. Convenient, fresh great tasting water at your fingertips
5. Easy to maintain and replace cartridges |
|
Performance |
1.
Product
water TDS content of less than 500 mg/l from Brackish feed water
of up to 1,500 mg/l
2. Product water TDS content of less than 300 mg/l from Tap feed
water |
|
|
Components |
|
|
Pretreatment |
1. Micron Filtration: 5-micron,
2" x 10" Spun Cartridge
2. Carbon Pre Filter 1: 10-micron
2" x 10" Extruded Carbon
Block
3. Carbon Pre Filter 2: 10-micron
2" x 10" GAC, Coconut shell |
|
Main
Treatment
(RO) |
1. Membrane
Elements: Standard Rejection CTA or TFC Membrane
elements 2" x 10" or 12" (D x L). Standard
Capacities 10 gpd for CTA, and 18 gpd for TFC. Optional
Capacities 16 & 20 gpd for CTA, and 24, 36, 50, 75 & 100 gpd for TFC.
2. Membrane Housing: PVC rated for up to 150 psig
applied pressure
3. Bracket: Styrene or Epoxy painted Aluminum |
Post
Treatment |
1.
Carbon Post Filter: In-line GAC, Coconut shell for odor removal
and taste improvement |
|
Tubing |
Standard
1/4" or 3/8" PE |
|
Valves |
Brine
Restrictor: Capillary type. Sizes vary from 10 to 100
gpd
Automatic Shut-off Valve: Shuts unit off when permeate tank
is full |
| Instruments |
Optional
Pressure Gauge and Conductivity Monitor |
|
Options |
|
| Upgrades |
Suffix,
Capacities and Description |
| |
1- |
2- |
3- |
4- |
5- |
6- |
7- |
| A-
Membrane Elements |
CTA-16 |
CTA-22 |
TFC-24 |
TFC-36 |
TFC-50 |
TFC-75 |
TFC-100 |
|
B- Pressurized
Tank |
Amtrol-10 |
ROM-4 |
ROM-15 |
ROM-20 |
ROM-30 |
ROM-40 |
ROM-80 |
|
C-
Tubing |
1-
3/8" for faster fill (Standard with larger capacities 4-
thru 7-) |
| D-
Faucet |
1-
With Air Gap, Model AGLC
2- Colored (A
= Almond, B = Black, W = White) |
| Add-ons
|
| E-
Booster Pump |
1-
Low Flow Model No. 6800
2- High Flow Model
No. 8800
Required
for low line pressure. Will boost feed pressure to the
recommended 60 psig |
| F-
Permeate Pump |
1-
Driven by brine energy, Requires no electricity.
Reduces
waste brine to drain by 80%, Fills permeate tank up to 5 times faster and increases its
pressure |
| G-
Delivery Pump |
1-
Low Flow 1.4 gpm
2- High Flow 3.0
gpm
Required
for remote installations where water supply does not have
enough pressure to reach the unit. |
| H-
Pressure Gauge |
1-
0-160 psig with 1/8" stem
For
pressure indication of feed water supply |
| I-
Water Quality Monitor |
1-
TDS
Green/ Red Status Light Indicator, provides instant check of
system performance and alerts for membrane replacement. |
| J-
UV Light |
1-
For
Bacteria control in feed water, 4-watt with transformer |
| K-
Specialty Filters |
Different
cartridges for
removal of Lead, Heavy metals, VOC, Giardia etc. available
upon request. Please consult with Modular Systems |
Example:
RO40-A5-B3-F1-I1-J1
Denotes 4-Stage Standard line RO System with 50 gpd TFC
Membrane, 15 gal RO-Mate Tank, with Permeate Pump, Permeate
Quality Monitor and UV Light disinfection |
|
|